土木工程建筑外文文献及翻译英语论文.doc

上传人:文库蛋蛋多 文档编号:2325083 上传时间:2023-02-11 格式:DOC 页数:13 大小:89KB
返回 下载 相关 举报
土木工程建筑外文文献及翻译英语论文.doc_第1页
第1页 / 共13页
土木工程建筑外文文献及翻译英语论文.doc_第2页
第2页 / 共13页
土木工程建筑外文文献及翻译英语论文.doc_第3页
第3页 / 共13页
土木工程建筑外文文献及翻译英语论文.doc_第4页
第4页 / 共13页
土木工程建筑外文文献及翻译英语论文.doc_第5页
第5页 / 共13页
点击查看更多>>
资源描述

《土木工程建筑外文文献及翻译英语论文.doc》由会员分享,可在线阅读,更多相关《土木工程建筑外文文献及翻译英语论文.doc(13页珍藏版)》请在三一办公上搜索。

1、土木工程建筑外文文献及翻译-英语论文土木工程建筑外文文献及翻译Cyclic behavior of steel moment frameconnections under varying axial load and lateraldisplacementsAbstractThis paper discusses the cyclic behavior of four steel moment connections tested under variable axial load and lateral displacements. The beam specim- ens consiste

2、d of a reducedbeam section, wing plates and longitudinal stiffeners. The test specimens were subjected to varying axial forces and lateral displace- ments to simulate the effects on beams in a Coupled-Girder Moment-Resisting Framing system under lateral loading. The test results showed that the spec

3、im- ens responded in a ductile manner since the plastic rotations exceeded 0.03 rad without significant drop in the lateral capacity. The presence of the longitudin- al stiffener assisted in transferring the axial forces and delayed the formation of web local buckling.1. Introduction Aimed at evalua

4、ting the structural performance of reduced-beam section(RBS) connections under alternated axial loading and lateral displacement, four full-scale specimens were tested. These tests were intended to assess the performance of the moment connection design for the Moscone Center Exp- ansion under the De

5、sign Basis Earthquake (DBE) and the Maximum Considered Earthquake (MCE). Previous research conducted on RBS moment connections 1,2 showed that connections with RBS profiles can achieve rotations in excess of 0.03 rad. However, doubts have been cast on the quality of the seismic performance of these

6、connections under combined axial and lateral loading.The Moscone Center Expansion is a three-story, 71,814 m2 (773,000 ft2) structure with steel moment frames as its primary lateral force-resisting system. A three dimensional perspective illustration is shown in Fig. 1. The overall height of the bui

7、lding, at the highest point of the exhibition roof, is approxima- tely 35.36 m (116ft) above ground level. The ceiling height at the exhibition hall is 8.23 m (27 ft) , and the typical floor-to-floor height in the building is 11.43 m (37.5 ft). The building was designed as type I according to the re

8、qui- rements of the 1997 Uniform Building Code.The framing system consists of four moment frames in the EastWest direct- ion, one on either side of the stair towers, and four frames in the NorthSouth direction, one on either side of the stair and elevator cores in the east end and two at the west en

9、d of the structure 4. Because of the story height, the con- cept of the Coupled-Girder Moment-Resisting Framing System (CGMRFS) was utilized.By coupling the girders, the lateral load-resisting behavior of the moment framing system changes to one where structural overturning moments are resisted part

10、ially by an axial compressiontension couple across the girder system, rather than only by the individual flexural action of the girders. As a result, a stiffer lateral load resisting system is achieved. The vertical element that connects the girders is referred to as a coupling link. Coupling links

11、are analogous to and serve the same structural role as link beams in eccentrically braced frames. Coupling links are generally quite short, having a large shear- to-moment ratio.Under earthquake-type loading, the CGMRFS subjects its girders to wariab- ble axial forces in addition to their end moment

12、s. The axial forces in theFig. 1. Moscone Center Expansion Project in San Francisco, CAgirders result from the accumulated shear in the link.2.Analytical model of CGMRFNonlinear static pushover analysis was conducted on a typical one-bay model of the CGMRF. Fig. 2 shows the dimensions and the variou

13、s sections of the model. The link flange plates were 28.5 mm 254 mm (1 1/8 in 10 in) and the web plate was 9.5 mm 476 mm (3 /8 in 18 3/4 in). The SAP 2000 computer program was utilized in the pushover analysis 5. The frame was characterized as fully restrained(FR). FR moment frames are those frames

14、for 1170土木工程建筑外文文献及翻译which no more than 5% of the lateral deflections arise from connection deformation 6. The 5% value refers only to deflection due to beamcolumn deformation and not to frame deflections that result from column panel zone deformation 6, 9. The analysis was performed using an expect

15、ed value of the yield stress and ultimate strength. These values were equal to 372 MPa (54 ksi) and 518 MPa (75 ksi), respectively. The plastic hinges loaddeformation behavior was approximated by the generalized curve suggested by NEHRP Guidelines for the Seismic Rehabilitation of Buildings 6 as sho

16、wn in Fig. 3. y was calcu- lated based on Eqs. (5.1) and (5.2) from 6, as follows: PM hinge loaddeformation model points C, D and E are based on Table 5.4 from 6 for y was taken as 0.01 rad per Note 3 in 6, Table 5.8. Shear hinge load- loaddeformation model points C, D and E are based on Table 5.8 6

17、, Link Beam, Item a. A strain hardening slope between points B and C of 3% of the elastic slope was assumed for both models.The following relationship was used to account for momentaxial load interaction 6:where MCE is the expected moment strength, ZRBS is the RBS plastic section modulus (in3), is t

18、he expected yield strength of the material (ksi), P is the axial force in the girder (kips) and is the expected axial yield force of the RBS, equal to (kips). The ultimate flexural capacities of the beam and the link of the model are shown in Table 1.Fig. 4 shows qualitatively the distribution of th

19、e bending moment, shear force, and axial force in the CGMRF under lateral load. The shear and axial force in the beams are less significant to the response of the beams as compared with the bending moment, although they must be considered in design. The qualita- tive distribution of internal forces

20、illustrated in Fig. 5 is fundamentally the same for both elastic and inelastic ranges of behavior. The specific values of the internal forces will change as elements of the frame yield and internal for- ces are redistributed. The basic patterns illustrated in Fig. 5, however, remain the same.Inelast

21、ic static pushover analysis was carried out by applying monotonicallyincreasing lateral displacements, at the top of both columns, as shown in Fig. 6. After the four RBS have yielded simultaneously, a uniform yielding in the web and at the ends of the flanges of the vertical link will form. This is

22、the yield mechanism for the frame , with plastic hinges also forming at the base of the columns if they are fixed. The base shear versus drift angle of the model is shown in Fig. 7 . The sequence of inelastic activity in the frame is shown on the figure. An elastic component, a long transition (cons

23、equence of the beam plastic hinges being formed simultaneously) and a narrow yield plateau characterize the pushover curve. The plastic rotation capacity, qp, is defined as the total plastic rotation beyond which the connection strength starts to degrade below 80% 7. This definition is different fro

24、m that outlined in Section 9 (Appendix S) of the AISC Seismic Provisions 8, 10. Using Eq. (2) derived by Uang and Fan 7, an estimate of the RBS plastic rotation capacity was found to be 0.037 rad:Fyf was substituted for RyFy 8, where Ry is used to account for the differ- ence between the nominal and

25、 the expected yield strengths (Grade 50 steel, Fy=345 MPa and Ry =1.1 are used).土木工程建筑外文文献及翻译3. Experimental programThe experimental set-up for studying the behavior of a connection was based on Fig. 6(a). Using the plastic displacement dp, plastic rotation gp, and plastic story drift angle qp shown

26、 in the figure, from geometry, it follows that:And: in which d and g include the elastic components. Approximations as above are used for large inelastic beam deformations. The diagram in Fig. 6(a) suggest that a sub assemblage with displacements controlled in the manner shown in Fig. 6(b) can repre

27、sent the inelastic behavior of a typical beam in a CGMRF.The test set-up shown in Fig. 8 was constructed to develop the mechanism shown in Fig. 6(a) and (b). The axial actuators were attached to three 2438 mm 1219 mm 1219 mm (8 ft 4 ft 4 ft) RC blocks. These blocks were tensioned to the laboratory f

28、loor by means of twenty-four 32 mm diameter dywidag rods. This arrangement permitted replacement of the specimen after each test.Therefore, the force applied by the axial actuator, P, can be resolved into two or thogonal components, Paxial and Plateral. Since the inclination angle of the axial actua

29、tor does not exceed 3.0, therefore Paxial is approximately equal to P 4. However, the lateral component, Plateral, causes an additional moment at the beam-to column joint. If the axial actuators compress the specimen, then the lateral components will be adding to the lateral actuator forces, while i

30、f the axial actuators pull the specimen, the Plateral will be an opposing force to the lateral actuators. When the axial actuators undergo axial actuators undergo a lateral displacement _, they cause an additional moment at the beam-to-column joint (P- effect). Therefore, the moment at the beam-to c

31、olumn joint is equal to: where H is the lateral forces, L is the arm, P is the axial force and _ is the lateral displacement.Four full-scale experiments of beam column connections were conducted.The member sizes and the results of tensile coupon tests are listed in Table 2All of the columns and beam

32、s were of A572 Grade 50 steel (Fy 344.5 MPa). The actual measured beam flange yield stress value was equal to 372 MPa (54 ksi), while the ultimate strength ranged from 502 MPa (72.8 ksi) to 543 MPa (78.7 ksi).Table 3 shows the values of the plastic moment for each specimen (based on measured tensile

33、 coupon data) at the full cross-section and at the reduced section at mid-length of the RBS cutout.The specimens were designated as specimen 1 through specimen 4. Test specimens details are shown in Fig. 9 through Fig. 12. The following features were utilized in the design of the beamcolumn connecti

34、on:The use of RBS in beam flanges. A circular cutout was provided, as illustr- ated in Figs. 11 and 12. For all specimens, 30% of the beam flange width was removed. The cuts were made carefully, and then ground smooth in a direct- tion parallel to the beam flange to minimize notches.Use of a fully w

35、elded web connection. The connection between the beam web and the column flange was made with a complete joint penetration groove weld (CJP). All CJP welds were performed according to AWS D1.1 Structural Welding CodeUse of two side plates welded with CJP to exterior sides of top and bottom beam flan

36、- ges, from the face of the column flange to the beginning of the RBS, as shown in Figs. 11 and 12. The end of the side plate was smoothed to meet the beginning of the RBS. The side plates were welded with CJP with the column flanges. The side plate was added to increase the flexural capacity at the

37、 joint location, while the smooth transition was to reduce the stress raisers, which may initiate fractureTwo longitudinal stiffeners, 95 mm 35 mm (3 3/4 in 1 3/8 in), were welded with 12.7 mm (1/2 in) fillet weld at the middle height of the web as shown in Figs. 9 and 10. The stiffeners were welded

38、 with CJP to column flanges.Removal of weld tabs at both the top and bottom beam flange groove welds. The weld tabs were removed to eliminate any potential notches introduced by the tabs or by weld discontinuities in the groove weld run out regionsUse of continuity plates with a thickness approximat

39、ely equal to the beam flange thickness. One-inch thick continuity plates were used for all specimens.While the RBS is the most distinguishing feature of these test specimens, the longitudinal stiffener played an important role in delaying the formation of web local buckling and developing reliable c

40、onnection performance土木工程建筑外文文献及翻译4. Loading history Specimens were tested by applying cycles of alternated load with tip displacement increments of _y as shown in Table 4. The tip displacement of the beam was imposed by servo-controlled actuators 3 and 4. When the axial force was to be applied, act

41、uators 1 and 2 were activated such that its force simulates the shear force in the link to be transferred to the beam. The variable axial force was increased up to 2800 kN (630 kip) at +0.5_y. After that, this lo- ad was maintained constant through the maximum lateral displacement. maximum lateral d

42、isplacement. As the specimen was pushed back the axial force remained constant until 0.5 y and then started to decrease to zero as the specimen passed through the neutral position 4. According to the upper bound for beam axial force as discussed in Section 2 of this paper, it was concluded that P =2

43、800 kN (630 kip) is appropriate to investigate this case in RBS loading. The tests were continued until failure of the specimen, or until limitations of the test set-up were reached.5. Test resultsThe hysteretic response of each specimen is shown in Fig. 13 and Fig. 16. These plots show beam moment

44、versus plastic rotation. The beam moment is measured at the middle of the RBS, and was computed by taking an equiva- lent beam-tip force multiplied by the distance between the centerline of the lateral actuator to the middle of the RBS (1792 mm for specimens 1 and 2, 3972 mm for specimens 3 and 4).

45、The equivalent lateral force accounts for the additional moment due to P effect. The rotation angle was defined as the lateral displacement of the actuator divided by the length between the centerline of the lateral actuator to the mid length of the RBS. The plastic rotation was computed as follows

46、4:where V is the shear force, Ke is the ratio of V/q in the elastic range. Measurements and observations made during the tests indicated that all of the plastic rotation in specimen 1 to specimen 4 was developed within the beam. The connection panel zone and the column remained elastic as intended b

47、y design.5.1. Specimens 1 and 2The responses of specimens 1 and 2 are shown in Fig. 13. Initial yielding occurred during cycles 7 and 8 at 1_y with yielding observed in the bottom flange. For all test specimens, initial yielding was observed at this location and attributed to the moment at the base

48、of the specimen 4. Progressing through the loading history, yielding started to propagate along the RBS bottom flange. During cycle 3.5_y initiation of web buckling was noted adjacent to the yielded bottom flange. Yielding started to propagate along the top flange of the RBS and some minor yielding

49、along the middle stiffener. During the cycle of 5_y with the increased axial compression load to 3115 KN (700 kips) a severe web buckle developed along with flange local buckling. The flange and the web local buckling became more pronounced with each successive loading cycle. It should be noted here that the bottom flan

展开阅读全文
相关资源
猜你喜欢
相关搜索

当前位置:首页 > 建筑/施工/环境 > 项目建议


备案号:宁ICP备20000045号-2

经营许可证:宁B2-20210002

宁公网安备 64010402000987号