1、Installation of Electrical Equipment in Hazardous Areas,Denial of Ignition Sources to flammable Gases,It cannot be stressed how important the philosophies followed to deny ignition sources to flammable gases are.The smallest ignition source can lead to the most dire consequences,Both far away Deepwa

2、ter Horizon,Gulf of Mexico,April 2010,And close to home-Pingyu Coal&Electric Co Ltd,Yuzhou,Henan Province,October 2010,This presentation is based on the International Elecrotechnical Commissions publication IEC-60079,There are other publications such as the National Electric Code(NEC)in the USA that

3、 have also produced standards for hazardous areas but the equipment in this project will be to IEC standards,The IEC has over a century of experience producing electrical standardsThe first hazardous area standards were created for the mining industry and then expanded to include the oil and gas sec

4、torIEC standards are not frozen in time but evolve for many reasons such as new materials being produced,technical advances are made and findings from disaster enquires to name but a few These standards are written to provide the best possible protection in the event of a gas escape utilising experi

5、ence of prior disasters and the leading experts in the hazardous area field,Flammable gases require ONLY ONE source of ignitionAll equipment MUST comply with the regulationsDisaster news stories usually say there was AN explosionAll regulations MUST be adhered to=There can be no exceptions,The zones

6、 for this vessel can be found on drawing M40188-1030015-Hazardous Area Plan,Plus-all equipment in exterior locations which is capable of operation after a shutdown is to be suitable for installation in Zone 2 locations,There are various philosophies that are defined by the IEC to deny source of igni

7、tion,Note;There is a philosophy hierarchy,Zone 0 equipment can be used in Zones 1&2,Zone 1 equipment can be used in Zone 2,List of Hazardous Areas on Hai Yang Shi You 981,Bell nipple zone 1Shale shakers-zone 1Heli fuel area-zone 1Battery locker-zone 1Paint locker-zone 1Below heli deck-zone 1Crown zo

8、ne 1Mud pits-zone 2Drill floor-zone 2Riser storage-zone 2Vents from enclosed hazardous areas zone 2Loading stations port and starboard zone 2all equipment in exterior locations which is capable of operation after a shutdown is to be suitable for installation in Zone 2 locations.,Tips on inspection o

9、f Ex equipment;(A full checklist is provided in the handout)Equipment is correct for ZoneAll cables must be armouredGlands for Exd should be Exd or ExdeGlands for Exe should be Exe or ExdeArmour to be clamped by the glandFor Ex equipment blanks to be Ex ratedFor Exe equipment the glands and blanks t

10、hread length should be minimum 6mm or IP washer and internal lockout,When earth ring is used,this must be located between gland shoulder and IP washerExd,Exe equipment earth wire should be minimum 2.5mm2 up to 16mm2 power conductorExi equipment earth wire should be minimum 4mm2All terminations shoul

11、d only have one conductor per terminalAll terminations should be correct and tight,Wire insulation should be maintain right up to the metal of the terminalCrimping tools of the hand rachet type must be usedAll spare conductors must be terminated both endsInsulation resistance test to be carried out,

12、Equipment is Incorrect for zone,Uncertified for zone,Correct certification,Correct glands and installed to manufacturers instructions,As above gland incorrectly installed,Correct size of gland,Use of tape,Blank plug uncertified,Uncertified blank,Blank plug to be certified and correctly installed,Exe

13、 locknut required,Incorrect use of earth ring,Correct use of earth ring,Two cores one terminal,Correct connection of two cores into one terminal,Incorrect termination,Terminal rail to be fixed and free from vibration,Exposed conductors,Spare conductors to be terminated,Cable support,Incorrect use of

14、 tools,Equipment is labeled correctlyLabel to include;The name of the manufacturer or his registered trademarkThe manufacturers type identificationThe symbol ExThe symbol for each type of protection usedThe symbol of the gas group for that equipmentFor group II electrical equipment,the symbol for th

15、e temperature classA serial number except for small equipment and accessories,All the above photos are indeed from our rig the Hai Yang Shi You 981.It is very important for everyone involved in installations in hazardous areas to have knowledge of the dangers and consequences that one simple mistake or compromise for schedule can soon become a disaster.,