《FROG 仪表英文说明书.doc》由会员分享,可在线阅读,更多相关《FROG 仪表英文说明书.doc(13页珍藏版)》请在三一办公上搜索。
1、防水仪表英文说明书第一页 封面FROG SERIES WEIGHING INDICATORUSERS MANUAL(LED, LCD BATTERY VRSION) 第二页Please read the manual carefully before operation!第三页 目录 第四页 型号定义Model is defined as following:Frog 0 - Bit 8, display color, refer to NoteBit 7, panel light type, “1” for normal; “2” for brightBit 6, precision lev
2、el, “1” for normal; “2” for highBit 5, back up, no definition nowBit 4, waterproof or not, “1” for No “2” for YesBit 3, battery type, “1” for battery “2” for Linth “3” for dryBit 2, display, “E” for LED display; “C” for LCD displayBit 1, series, “Frog” seriesNote: When Bit 2 is “E” with LED display,
3、 value defined as following:1 for white; 2 for green; 3 for yellow green4 for yellow; 5 for amber; 6 for red7 for blue; 8 for red-green-yellow; 9 for red blue ribbonWhen Bit 2 is “C” with LCD display, color for backlight is defined as following:1 for white; 2 for green; 3 for yellow green4 for yello
4、w; 5 for amber; 6 for red7 for blue; 8 for seven color(red,green,yellow,blue,ribbon,blue,white (selectable) Example 1: Model FrogE120-117 stands for Frog series, Led display, with rechargeable battery, water proof, normal precision, with normal panel brightness, display color blueExample 2: Model Fr
5、ogC120-118 stands for Frog series, Lcd display, with rechargeable battery, water proof, normal precision, with normal panel brightness, backlight color is seven-color第五页 主要参数Chapter One Specification1, Verified counts N=3000;2, Sampling speed: 10 times/sec3, Load cell sensitivity range: 1.53mV/V4, L
6、oad cell connection number: 14 at 350 ohm5, Division: 1/2/5/10/20/506, Display: 6 bits LED, 9 status indications(LED version) 6 bits LCD, 13 status indications(LCD version)7 Communication interface(optional): RS232, serial sending, able to connect to scoreboard or PC8 Power supply: AC 100240V/5060Hz
7、 adatper DC 6V/4AH(when voltage is below 5.4V, it will indicate)9, Charge currency: 1A10, Working temperature range: -104011,Transportation temperature range: -2555第六页(显示与键盘)一、Chapter Two Front ViewFront View: LED versionIndication and key definition:Kg: To indicate the current weight unit is Kg;g:
8、To indicate the current weight unit is g;lb: To indicate the current weight unit is lb;+-: To indicate low batteryZero: To indicate the weighing data is at zero point;Stable: To indicator the weighing data is stable;Net: To indicate the current weight is net;Accum: To indicate in accumulation weight
9、 mode;Keep: To indicate the current weight is peak value;AC: To indicate current power supply is Ac;Count.: To indicate its under counting function (the last decimal point)Front View LCD versionIndication and key definition:Kg: To indicate the current weight unit is Kg;g: To indicate the current wei
10、ght unit is g;lb: To indicate the current weight unit is lb;Pcs: To indicate its under counting function;Battery: To indicate its low battery;HIGH: To indicate current weight reaches the high value;OK: To indicate the current weight is between high and low value;LOW: To indicate current weight reach
11、es the low value;Zero: To indicate the weighing data is at zero point;Stable: To indicator the weighing data is stable;Net: To indicate the current weight is net;Accum: To indicate in accumulation weight mode;Keep: To indicate the current weight is peak value;AC: To indicate current power supply is
12、Ac;Keyboards Zero key: To zero within the manual zero range, and current weight will be zero;Tare key: To tare and net indication will be on, and it will display net weight;Accum key: To accumulate and get accumulation times/accumulation value;Count key: To enter into counting function;Keep key: To
13、get peak hold function;Enter key: To confirm and set up for function;ON/OFF key: To turn on when it if off and to turn off when it is on; 二、Chapter Three Interface(传感器连接,加图)Load cell interface1, The load cell connector is 7-pin, round, each pin is defined as following:2, If 4-wire cable is adopted,
14、then short connect +E and +S, -E and S;3, Pin definition is as following:Pin 1: -INPin 2: +INPin 3: +EPin 4: +SPin 5:-SPin 6: -EPin 7: Shield三、Chapter Five Operation(操作说明)1, On/OffPress on/off key to turn on or turn off the weighing indicator. (Power supply is DC). Press on/off key to show charge st
15、atus if indicator is in charge. Press again, then back to weighing status.Note: If AC is connected, indicator will auto turn on and gets into charge and weighing status. 2, Zero operationAuto zero: If the weighing data is out of auto zero range, it will display Err-3 to indicate it cant find zero po
16、int. Then unload the commodity on the weighing platform, it can enter into normal weighing status.Manual zero: Its valid at gross weighing status. Press zero key to back to gross zero point.3, Tare operationPress tare key to regard the current weighing data as tare value, the net indication will be
17、on. Unload the current weighing, it will display the negative tare value. Press tare again to back to gross zero point.4, Accumulation operationWhen the weighing data is not zero, press accum key, the current weighing data will be accumulated. And it will display ADD-xx to show the accumulation time
18、s (the max. times is 99) then it goes back to weighing status. The accumulation indication will be on. When the weighing data is zero, press accum key, it will display the accumulation times, press accum key again, it will display accumulation value, press accum key again, it goes back to weighing s
19、tatus. While displaying accumulation times or accumulation value, press enter key to clear the accumulation times or accumulation value, the accumulation indication will be off and indicator goes back to weighing status.5, Counting functionPress count key after putting some samples at weighing statu
20、s, it will display n=0000, press key to input the quantity of the samples, then press enter key, it gets the unit weight of the sample and the unit weight will be saved in the memory size. Then it enters into counting function. If there is something wrong during sampling, it will display Err-04 and
21、loads to indicate the failure of the current sampling. Indicator will get the unit weight of last sampling from the memory size. Press Count key again, it will quit counting status and back to weighing status. (When the display is LED, the last decimal point is on to indicate that its at counting fu
22、nction. When the display is LCD, the pcs is on to indicate that its at counting function.)6, Peak holding functionPress keep key at weighing status(make ensured that in users defined setting, parameter FNCf X=2), the keep indication will be on, and it will enter into peak holding function. Press kee
23、p key again to quit peak holding function, the keep indication will be off and back to weighing status.四、Chapter Four users defined setting(用户功能设置)1.LED, single color display versionPress enter key for 2 seconds at weighing status, then indicator will enter into users defined setting mode. Press ent
24、er key to switch parameter from FNC1-x FNC2-x FNC3-x END and press to select the value for each parameter. Press enter key again for 2 seconds, then it will return back to the weighing status. Following is the definition for each parameter:Press key to switch the value for each parameter;Press enter
25、 key to confirm the value and go to next parameter;FNC1 To keep the factory default setting or notX=1 No,X=2 Yes.If the selection is X=2, press tare key to view the default setting for each parameter. Please refer to Note for default setting for each parameter.FNC2 Power-saving mode settingX=1 No po
26、wer-savingX=2 Power-saving mode 1. When the weighing data is stable for some time, indicator directly enters into power-saving model and indicator goes back to weighing mode when weighing data is unstableX=3 Power-saving mode 2. When the weighing data is stable for some time, the brightness of displ
27、ay will goes down and then indicator goes into power-saving mode. Indicator goes back to weighing mode when weighing data is unstableNote: Power-saving mode is only available when power supply is DC.FNC3 Set up for time when it enters into power-saving modeX=1 After 30 seconds no change of weighing
28、data, it enters into power-saving modeX=2 After 60 seconds no change of weighing data, it enters into power-saving modeX=3 After 120 seconds no change of weighing data, it enters into power-saving modeThis parameter is only available when FNC2 X=2/3 and power supply is DC.FNC4 Set up for time when i
29、t is auto power offX=1 No auto power offX=2 Indicator will be auto power off after 10 minutes no weighing data changeX=3 Indicator will be auto power off after 20 minutes no weighing data changeX=4 Indicator will be auto power off after 30 minutes no weighing data changeThis is only valid when power
30、 supply is DC.FNC5 BackupFNC6 Set up for display brightnessX=1 Low brightnessX=2 Middle brightnessX=3 High brightnessFNC7 Backup/FNC8 Backup/FNC9 Backup/FNCa Backup/FNCb BackupFNCc Set up for decimal point shapeX=1 “” signalX=2 “ ,”signalFNCd Set up for digital filter intensityX=1 No digital filterX
31、=2 Low digital filter intensityX=3 Middle digital filter intensityX=4 Strong digital filter intensityPlease select the intensity according to the vibration of weighing environment;FNCe BackupFNCf Set up for peak holding functionX=1 No peak hold fucntionX=2 Peak hold functionFNCg Set up for baud rate
32、X=1 9600X=2 4800X=3 2400FNCh Set up for RS232 data formatX=1 No set up for RS232 data formatX=2 Able to set up for RS232 data formatFNCi BackupFNCj Set up for high/low timeX=1 Indicate high/low after stablilityX=2 Indicae high/low before stabilityLO Set up for low valuePress to input value of the lo
33、w targetUP set up for high valuePress to input value of the high targetEND1Note: Factory default settingFNC1-1/FNC2-1/FNC3-1/FNC4/FNC6-3/FNCc-1/FNCd-1/FNCf-1/NCg-1/FNCh-1/FNCj-1LO(0/ UP(0)FNC5/ FNC7/ FNC8/ FNC9/ FNCa/ FNCb/ FNCe/ FNCi BACK UP2.LED, three- color display versionPress enter key for 2 s
34、econds at weighing status, then indicator will enter into users defined setting mode. Press enter key to switch parameter from FNC1-x FNC2-x FNC3-x END and press to select the value for each parameter. Press enter key again for 2 seconds, then it will return back to the weighing status. Following is
35、 the definition for each parameter:Press key to switch the value for each parameter;Press enter key to confirm the value and go to next parameter;FNC1 To keep the factory default setting or notX=1 NoX=2 YesIf the selection is X=2, press tare key to view the default setting for each parameter. Please
36、 refer to Note for default setting for each parameter.FNC2 Power-saving mode settingX=1 No power-savingX=2 Power-saving mode 1. When the weighing data is stable for some time, indicator directly enters into power-saving model and indicator goes back to weighing mode when weighing data is unstableX=3
37、 Power-saving mode 2. When the weighing data is stable for some time, the brightness of display will goes down and then indicator goes into power-saving mode. Indicator goes back to weighing mode when weighing data is unstableNote: Power-saving mode is only available when power supply is DC.FNC3 Set
38、 up for time when it enters into power-saving modeX=1 After 30 seconds no change of weighing data, it enters into power-saving modeX=2 After 60 seconds no change of weighing data, it enters into power-saving modeX=3 After 120 seconds no change of weighing data, it enters into power-saving modeThis p
39、arameter is only available when FNC2 X=2/3 and power supply is DC.FNC4 Set up for time when it is auto power offX=1 No auto power offX=2 Indicator will be auto power off after 10 minutes no weighing data changeX=3 Indicator will be auto power off after 20 minutes no weighing data changeX=4 Indicator
40、 will be auto power off after 30 minutes no weighing data changeFNC5 BackupFNC6 Set up for display brightnessX=1 Low brightnessX=2 Middle brightnessX=3 High brightnessFNC7 Set up for color of diplsayX=1 Red/X=2 Green/X=3 Yellow orX=1 Red/X=2 Blue/X=3 purpleFCN8 Set up for color of decimal pointX=1 R
41、ed/X=2 Green/X=3 Yellow orX=1 Red/X=2 Blue/X=3 purpleFNC9 Set up for color of cursorX=1 Red/X=2 Green/X=3 Yellow orX=1 Red/X=2 Blue/X=3 purpleFNCa Set up for combined colorX=1 Red/X=2 Green/X=3 Yellow orX=1 Red/X=2 Blue/X=3 purpleFNCb Set up for auto color changeX=1 No changeX=2 Change the color eve
42、ry 10 minutesIf HIGH/LOW value is saved, this function is invalidFNCc Set up for decimal point shapeX=1 “” signalX=2 “ ,”signalFNCd Set up for digital filter intensityX=1 No digital filterX=2 Low digital filter intensityX=3 Middle digital filter intensityX=4 Strong digital filter intensityPlease sel
43、ect the intensity according to the vibration of weighing environment;FNCe BackupFNCf Set up for peak holding functionX=1 No peak hold fucntionX=2 Peak hold functionFNCg Set up for baud rateX=1 9600X=2 4800X=3 2400FNCh Set up for RS232 data formatX=1 No set up for RS232 data formatX=2 Able to set up
44、for RS232 data formatFNCi BackupFNCj Set up for high/low timeX=1 Indicate high/low after stablilityX=2 Indicae high/low before stabilityLO Set up for low valuePress to input value of the low targetUP set up for high valuePress to input value of the high targetEND1Note: Factory default settingFNC1-1/
45、FNC2-1/FNC3-1/FNC4-1/FNC6-3/FNC7-1/FNC8-1/FNC9-1/FNCa-1/FNCb-1/FNCc-1/FNCd-1/FNCf-1/FNCg-1/FNCh-1/FNCj-1 LO(0)UP(0)FNC5/FNCe/ FNCi BACK UP3.LCD, single color backlight versionPress enter key for 2 seconds at weighing status, then indicator will enter into users defined setting mode. Press enter key
46、to switch parameter from FNC1-x FNC2-x FNC3-x END and press to select the value for each parameter. Press enter key again for 2 seconds, then it will return back to the weighing status. Following is the definition for each parameter:Press key to switch the value for each parameter;Press enter key to confirm the value and go to next parameter;FNC1 To keep the factory default setting or notX=1 NoX=2 YesIf the selection is X=2, press tare key to view the default setting for each parameter. Please refer to Note for default setting for each parameter.