《C系列离心冷水机组.doc》由会员分享,可在线阅读,更多相关《C系列离心冷水机组.doc(12页珍藏版)》请在三一办公上搜索。
1、一、产品介绍1、产品概述1.1 产品定义第二章 C 系列离心式水冷冷水机组A格力 C 系列离心式冷水机组经多年潜心研究推出,采用了国际上先进的设计制造技术和微机控制系 统,集可靠性高、高效节能,运行平稳、调节范围宽等优点于一身。格力 C 系列离心式冷水机组在标准 工况下的制冷量范围为:1000 7800kW,采用环保制冷剂 R134a,具有 380V、6000V、10000V 三种规 格电源。可广泛用于大型办公楼宇、医院、学校、商场以及工艺流程。1.2 产品外形图3定频系列:380V 3N 50Hz:LSBLX1000G LSBLX4400G6000V 3 50Hz:LSBLX1000MG L
2、SBLX5200MG,LSBLX5600SMG LSBLX7800SMG10000V 50Hz:LSBLX1000HG LSBLX5200HG,LSBLX5600SHG LSBLX7800SHG 变频系列:LSBLX1000VG LSBLX4400VG1.3 产品主要特点专业设计权威测试高效叶轮高效换热无级调节高级控制彩色液晶远程监控2、产品命名规则A二、产品性能参数表及测试工况1、产品性能参数表型号 LSBLX G100012001400160018002000220024002600280030003200冷量调节%10 100制冷量kW10001200140016001800200022
3、0024002600280030003200RT284341398456511568625682740796854909IPLVW/W5.966.026.106.216.386.436.546.536.606.646.536.57噪声dB(A)888888888890909090909092压缩机型式单级电机电源V-Ph-Hz380/6000/10000V 3N 50Hz功率kW191227261293321354383418448480523554配电功率kW210250287322353389421460493528575609冷冻油灌注量L505050506060608080808080
4、蒸发器水流量3m /h172206241275310344378413447482516550水压降kPa757575757575759090909090流程数-222222222222接管尺寸mm200200200200250250250250250250300300冷凝器水流量m3/h215258301344387430473516559602645688水压降kPa707070707070708585858585流程数-222222222222接管尺寸mm200200200200250250250250250250300300接管方式法兰式外型尺寸宽mm36303630363036304
5、1504150415045304530453045304530深mm168016801680168019001900190020702070207021202120高mm206020602060206022502250225025002500250025002500机组重量净重kg57006000630066008800920094001080011200116001180012000运行重量kg62006600680071009800102001060012800130001320013500140003A型号 LSBLX G340036003800400044004800520056006
6、0006400680072007800冷量调节%10 100制冷量kW3400360038004000440048005200560060006400680072007800RT967102310811136125113641479159117061818193420442217IPLVW/W6.656.486.536.626.556.626.726.716.766.796.806.866.85噪声dB(A)92929292929595959595959595压缩机型式单级双级电机电源V-ph-Hz380/6000/10000V 3N 50Hz6000/10000V 3 50Hz功率kW582
7、63266268876482588095010101072113811951295配电功率kW640695728757840908968104511111179125213151425冷冻油灌注量L80100100100100100100125125125125125125蒸发器水流量m3/h58561965468875782689496310321101117012381342水压降kPa90115115115115115115125125125125125125流程数-2222222222222接管尺寸mm300300300300350350350350350400400400400冷凝器
8、水流量m3/h73177481786094610321118120412901376146215481677水压降kPa85100100100105105105125125125125125125流程数-2222222222222接管尺寸mm300350350350350350350400400450450450450接管方式法兰式外型尺寸宽mm4530475047504750475047504750535053505350535053505750深mm2120233023302330248024802480262026202820282028202920高mm2500275027502750
9、275027502750310031003100310031003300机组重量净重kg12200146001480015200158001620016600225002380025500261002650027000运行重量kg145001650017000175001800018500190002595027500294503020031000320003注: 以上选型适用于冷冻水出水温度 7,冷却水进水温度 32。 标准机组水侧承压 1.0MPa,可供选项 1.6MPa。 冷冻水,冷却水污垢系数 0.086m2 /kW。 表中 IPLV 值为机组按 GB/T 18430.1-2007 规
10、定工况的测试值。 机组性能参数表会因产品的改良有所改变,恕不另行通知。具体的参数请以产品铭牌为准。2、产品运行范围冷冻水冷却水出水温度 ( )进出水温差 ( )进水温度 ( )进出水温差 ( )5 152.5 816 353.5 83、产品能力修正3.1 制冷能力修正3三、产品安装1、产品安装注意事项1.1 机组位置与环境该部分内容同“CVE 系列高效直流变频离心式冷水机组”章节。2、产品安装基础及外形尺寸2.1 机组安装基础该部分内容同“CVE 系列高效直流变频离心式冷水机组”章节。 非特殊说明,以下长度单位均为:mm300机组本体底板用户自备A 底座钢板A-AF50030070冷凝器中心线
11、 蒸发器中心线地脚螺栓M30(用户自备) 螺母M30(用户自备)A垫圈30(用户自备)灌浆高度500大于100250350地面机组本体底板 橡胶垫板厚15底座钢板 厚20(用户自备)125250 E 机组就位后灌浆 200200A机组安装基础示意图A机组型号EF机组型号EFLSBLX1000(H)(V)G27901430LSBLX3600(H)(V)G37902080LSBLX1200(H)(V)G27901430LSBLX3800(H)(V)G37902080LSBLX1400(H)(V)G27901430LSBLX4000(H)(V)G37902080LSBLX1600(H)(V)G279
12、01430LSBLX4400(H)(V)G37902230LSBLX1800(H)(V)G32901650LSBLX4800HG37902230LSBLX2000(H)(V)G32901650LSBLX5200HG37902230LSBLX2200(H)(V)G32901650LSBLX5600SHG41902370LSBLX2400(H)(V)G35901820LSBLX6000SHG41902370LSBLX2600(H)(V)G35901820LSBLX6400SHG41902570LSBLX2800(H)(V)G35901820LSBLX6800SHG41902570LSBLX3000
13、(H)(V)G35901870LSBLX7200SHG41902570LSBLX3200(H)(V)G35901870LSBLX7800SHG45902570LSBLX3400(H)(V)G3590187032.2 机组外形尺寸CEHID FGAB标记名称标记名称蒸发器冷却水出水冷凝器冷却水进水电控柜冷冻水进水压缩机冷冻水出水电机A机组尺寸单位:mm型号ABCDEFGHI冷冻水接口冷却水接口LSBLX1000(H)(V)G415017302150547555400655675350200200LSBLX1200(H)(V)G41501730215054755540065567535020020
14、0LSBLX1400(H)(V)G415017302150547555400655675350200200LSBLX1600(H)(V)G415017302150547555400655675350200200LSBLX1800(H)(V)G415019002250551555430735640430250250LSBLX2000(H)(V)G415019002250551555430735640430250250LSBLX2200(H)(V)G415019002250551555430735640430250250LSBLX2400(H)(V)G45302070250060160047082
15、0685430250250LSBLX2600(H)(V)G453020702500601600470820685430250250LSBLX2800(H)(V)G453020702500601600470820685430250250LSBLX3000(H)(V)G453021202500544595470825665470300300LSBLX3200(H)(V)G453021202500544595470825665470300300LSBLX3400(H)(V)G453021202500544595470825665470300300LSBLX3600(H)(V)G47502330275
16、0599780540895890525300350LSBLX3800(H)(V)G475023302750599780540895890525300350LSBLX4000(H)(V)G475023302750599780540895890525300350LSBLX4400(H)(V)G4750238027506849006358731152530350350LSBLX4800HG4750238027506849006358731152530350350LSBLX5200HG4750238027506849006358731152530350350LSBLX5600SHG5350262031
17、00684900635988825600350400LSBLX6000SHG535026203100684900635988825600350400LSBLX6400SHG5350282031006849506501030825600400450LSBLX6800SHG5350282031006849506501030825600400450LSBLX7200SHG5350282031006849506501030825600400450LSBLX7800SHG5750292033006911000700100592565040045033、产品安装及维修空间注:非特殊说明,以下长度单位均为:
18、mm拔顶部维修空间AA型号ABCDLSBLX1000(H)(V)G1500350015001220LSBLX1200(H)(V)G1500350015001220LSBLX1400(H)(V)G1500350015001220LSBLX1600(H)(V)G1500350015001220LSBLX1800(H)(V)G1500350015001220LSBLX2000(H)(V)G1500350015001220LSBLX2200(H)(V)G1500350015001220LSBLX2400(H)(V)G1500380016501320LSBLX2600(H)(V)G15003800165
19、01320LSBLX2800(H)(V)G1500380016501320LSBLX3000(H)(V)G1500380016501320LSBLX3200(H)(V)G1500380016501320LSBLX3400(H)(V)G1500380016501320LSBLX3600(H)(V)G1500400018001320LSBLX3800(H)(V)G1500400018001320LSBLX4000(H)(V)G1500400018001320LSBLX4400(H)(V)G1500400018001320LSBLX4800HG1500400018001320LSBLX5200HG1
20、500400018001320LSBLX5600SHG1500440018001520LSBLX6000SHG1500440018001520LSBLX6400SHG1500440018001520LSBLX6800SHG1500440018001520LSBLX7200SHG1500440018001520LSBLX7800SHG150048001800152034、产品电气安装4.1 高压离心机机组工程接线示意图:注:由于设计改进,机组外型可能会稍有更新,以实物为准。离心机组启动柜来自客户配 电柜的电源配线说明:(1) 线为从客户高压配电柜至启动柜的电源线,要求电源规格为 10kV 3 5
21、0Hz。电源线从启动柜 下端进入,线径要求随机组功率调整。(2) 线为从启动柜至离心机组主电机的动力线。动力线从启动柜下端出线,线径要求随机组功率调整。(3) 线为从客户低压配电柜至离心机组油泵控制柜的电源线(三相带零线、地线),线径要求为 2.5mm2或以上。电源规格为 380V 3N 50Hz。(4) 线为从启动柜至离心机组主控制柜的信号控制线(具体连接参看下图)。线径要求为连接“5”、 “6”号端子的为 2.5mm2 或以上,其余 1.0mm2 或以上。(5) 线为从离心机主控制柜至水泵控制柜及远程开关机的信号控制线(具体连接参看下图)。线径 要求为 1.0mm2 或以上。注:水泵控制柜
22、由客户提供。34.2 低压离心机机组工程接线示意图:高压离心机组工程接线原理图A注:由于设计改进,机组外型可能会稍有更新,以实物为准。低压柜主电源进线推荐下进方式,若客户需要进线,请拆卸启动柜顶部回字形过线孔。离心机组启动柜来自客户配 电柜的电源配线说明:(1) 线为从客户配电柜至启动柜的电源线(三相带零线、地线),要求电源规格为 380V 3N 50Hz。电源线从启动柜上端进入,线径要求随机组功率调整。(2) 线为从启动柜至离心机组主电机的动力线(星三角启动,6 根动力线,带地线)。动力线从启 动柜下端出线,线径要求随机组功率调整。(3) 线为从启动柜至离心机组油泵控制柜的电源线(三相带零线
23、、地线),线径要求为 2.5mm2 或以上。 (4) 线为从启动柜至离心机组主控制柜的信号控制线(具体连接参看下图)。线径要求为连接“5”、“6”号端子的为 2.5 mm2 或以上,其余 1.0mm2 或以上。(5) 线为从离心机主控制柜至水泵控制柜及远程开关机的信号控制线(具体连接参看下图)。线径 要求为 1.0mm2 或以上。注:水泵控制柜由客户提供。34.3 变频离心机机组工程接线示意图:低压离心机组工程接线原理图A注:由于设计改进,机组外型可能会稍有更新,以实物为准;变频柜以及机组根据功率不同,外形 尺寸上会有差异,变频柜的厂家不同,外形也会不同。离心机组变频柜变频 柜电 源进 线配线
24、说明:(1) 线为从低压进线柜(配电柜)至变频柜的电源线,要求电源规格为 380V 3 50Hz。电源线从启 动柜下端进入,线径要求随机组功率调整。(2) 线为从变频柜至离心机组主电机的动力线。动力线从启动柜下端出线,线径要求随机组功率调整。(3) 线为从客户低压配电柜至离心机组油泵控制柜的电源线(三相带零线、地线),线径要求为 2.5mm2或以上。电源规格为 380V 3N 50Hz。(4) 线为从变频柜至离心机组主控制柜的信号控制线(具体连接参看接线示意图)。信号线请使用 屏蔽双绞线(如下图所示);其中主控柜接线板的 1、2;5、6;7、8;11、12 号接线分别一组 双绞线,其中主控柜的
25、 5、6 端连接线必须使用公司出厂配带的通讯线,该通讯线屏蔽层就近接 至机组电控柜的接地端上,另一端绕有磁环的接至变频柜对应端口。3(5) 线为从离心机主控制柜至水泵控制柜及远程开关机的信号控制线(具体连接参看接线示意图)。线径要求为 1.0mm2 或以上。注:水泵控制柜由客户提供。(6) 务必保持强弱电分开,具体要求见下图。电机电缆、输入电源电缆、控制电缆应安装在不同的线 槽中,同时线槽和电缆的屏蔽层均需就近接地。变频柜电机电缆最小300mm(12in.)最小300mm(12in.) 输入电源电缆电机电缆电源电缆最小200mm(8in.)90最小500mm(20in.)A控制电缆(7) 变频
26、柜的使用将会引起电磁干扰,变频柜到电机及控制柜的线越长,受到的干扰越大。故变频柜 与主机之间的接线长度不应大于 50 米,如有特殊情况,请咨询供应商。A由于变频柜的厂家不同,工程接线会有所不同。请以柜体中所附的图纸为准。1)选用 ABB 厂家变频柜接线示意图如下:3图 1两个整流模块,两个逆变模块的变频柜电缆接线示意图图 2一个整流模块,两个逆变模块的变频柜电缆接线示意图图 3一个整流模块,一个逆变模块的变频柜电缆接线示意图 控制回路以及油泵柜的接线示意图2)选用南车厂家变频柜接线示意图如下 3 控制回路的接线示意图四、产品供货范围S= 标准配置件 O= 用户自备件 P= 用户选购件A供货内容数量规格类别备注主机1台S制冷剂-kgS润滑油-kgS低压启动柜1台S适于 380V 电压机组高压启动柜1台P适于 10kV、6kV 电压机组油过滤器1个P注:如需远程监控,请参照远程监控章节选购相关配件。