《USB键盘恢复触摸屏出厂设置.docx》由会员分享,可在线阅读,更多相关《USB键盘恢复触摸屏出厂设置.docx(4页珍藏版)》请在三一办公上搜索。
1、Resetting a PanelView Plus Version 6 or greater to factory default stateQuestionHow to reset a PanelView Plus Version 6 or greater to factory default state? This might be desirable after a failed firmware update, for example.Why does my PanelView Plus Version 6 or greater show the computer OS when p
2、owering up, with no Rockwell Software showing under Window Startup Progran?AnswerNote*: Requires an attached USB keyboard prior to accessing Maintenance mode.All user updates will be removed including user installed firmware updates and patches. All .MER files will be deleted.1. On PanelView Plus 6
3、models (firmware v6.x and greater), there is a small, recessed button labeled DEFAULT into which you can insert a thin non-conductive probe. This will restart the terminal in Maintenance mode.Note*: To access this menu from a fault state, press the Reset switch, then press and hold the Default switc
4、h until you see the menu.2. Use the down arrow on the keyboard to select Special BOOT Action.sTiiillContinue booting: with selected optionsDisplay resolution - AUTOuse the left arrow key to select Restore Factory3. Once Special BOOT Action is hi lighted Defaults.Continue booting with selected optionDisplay resolution - AUTO4. Use the up arrow to select Continue booting with selected options.Special BOOT Action - Restore Factory I)&FaultsDisplciy resolution - RUTO5. Click the Enter key on your keyboard to begin booting the PanelView Plus 6 to Factory Defaults.