《【BS英国标准】BS EN 611692 Radiofrequency connectors. Sectional specification. Radio frequen.doc》由会员分享,可在线阅读,更多相关《【BS英国标准】BS EN 611692 Radiofrequency connectors. Sectional specification. Radio frequen.doc(25页珍藏版)》请在三一办公上搜索。

1、BRITISH STANDARDBS EN61169-2:2007Radio-frequency connectors Part 2: Sectional specification Radio frequency coaxial connectors oftype 9,52The European Standard EN 61169-2:2007 has the status of aBritish StandardICS 31.220.10 BS EN 61169-2:2007National forewordThis British Standard was published by B

2、SI. It is the UK implementation ofEN 61169-2:2007. It is identical with IEC 61169-2:2007. It supersedesBS EN 61169-2:2002 which is withdrawn.The UK participation in its preparation was entrusted by Technical Committee EPL/46, Cables, wires and waveguides, radio frequency connectors and accessories f

3、or communication and signalling, to Subcommittee EPL/46/2, Radio frequency connectors and waveguides.A list of organizations represented on this committee can be obtained on request to its secretary.This publication does not purport to include all the necessary provisions of a contract. Users are re

4、sponsible for its correct application.Compliance with a British Standard cannot confer immunity from legal obligations.Amd. No.DateCommentsThis British Standard was published under the authority of the Standards Policy and Strategy Committeeon 31 May 2007 BSI 2007ISBN 978 0 580 50821 9Amendments iss

5、ued since publicationEUROPEAN STANDARDEN 61169-2NORME EUROPENNEEUROPISCHE NORMMarch 2007ICS 31.220.10Supersedes EN 61169-2:2001English versionRadio-frequency connectors - Part 2: Sectional specification -Radio frequency coaxial connectors of type 9,52(IEC 61169-2:2007)Connecteurs pour frquences radi

6、olectriques -Partie 2: Spcification intermdiaire - Connecteurs pour frquences radiolectriques de srie 9,52(CEI 61169-2:2007)Hochfrequenz-Steckverbinder - Teil 2: Rahmenspezifikation -Koaxiale HochfrequenzsteckverbinderTyp 9,52(IEC 61169-2:2007)This European Standard was approved by CENELEC on 2007-0

7、3-01. CENELEC members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European Standard the status of a national standard without any alteration.Up-to-date lists and bibliographical references concerning such national standards may be obta

8、ined on application to the Central Secretariat or to any CENELEC member.This European Standard exists in three official versions (English, French, German). A version in any other language made by translation under the responsibility of a CENELEC member into its own language and notified to the Centr

9、al Secretariat has the same status as the official versions.CENELEC members are the national electrotechnical committees of Austria, Belgium, Bulgaria, Cyprus, the Czech Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Mal

10、ta, the Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland and the United Kingdom.CENELECEuropean Committee for Electrotechnical Standardization Comit Europen de Normalisation Electrotechnique Europisches Komitee fr Elektrotechnische NormungCentral Secreta

11、riat: rue de Stassart 35, B - 1050 Brussels 2007 CENELEC -All rights of exploitation in any form and by any means reserved worldwide for CENELEC members.Ref. No. EN 61169-2:2007 E 9 EN 61169-2:2007ForewordThe text of document 46F/56/FDIS, future edition 2 of IEC 61169-2, prepared by SC 46F, R.F. and

12、 microwave passive components, of IEC TC 46, Cables, wires, waveguides, R.F. connectors, R.F. and microwave passive components and accessories, was submitted to the IEC-CENELEC parallel vote and was approved by CENELEC as EN 61169-2 on 2007-03-01.This European Standard supersedes EN 61169-2:2001.The

13、 main change introduced in EN 61169-2:2007 is that the maximum frequency is now 3 GHz. The following dates were fixed: latest date by which the EN has to be implementedat national level by publication of an identicalnational standard or by endorsement(dop)2007-12-01 latest date by which the national

14、 standards conflicting with the EN have to be withdrawnAnnex ZA has been added by CENELEC.(dow)2010-03-01Endorsement noticeThe text of the International Standard IEC 61169-2:2007 was approved by CENELEC as a EuropeanStandard without any modification.CONTENTS1Scope . 42Normative references .43Interfa

15、ce dimensions .43.1Interface .43.2Mechanical gauges.84Quality assessment procedures. .94.1General. . 94.2Ratings and characteristics .94.3Test schedule and inspection requirements . 114.4Procedures .135Instructions for preparation of detail specifications . 135.1General .135.2Identification of the d

16、etail specification .135.3Identification of the component .145.4Performance.145.5Marking, ordering information and related matters .145.6Selection of tests, test conditions and severities .145.7Blank detail specification pro-forma for type 9,52 connector .15Annex ZA (normative) Normative references

17、to international publications with theircorresponding European publications .20 Figure 1a Sliding male connector . 5Figure 1b Sliding female connector .5Figure 1 Sliding connector .5Figure 2a Screw coupling male connector . 6Figure 2b Screw coupling female connector . 6Figure 2 Screw coupling connec

18、tor .6Figure 3a Standard test male connector .7Figure 3b Standard test female connector .7Figure 3 Standard test connectors .7Figure 4 Gauge pins for outer contact of socket connector .8Figure 5 Gauge pins for centre contact of socket connector . 9Table 1 Ratings and characteristics . 10Table 2 Acce

19、ptance tests . 11Table 3 Periodic tests . 12 RADIO-FREQUENCY CONNECTORS Part 2: Sectional specification Radio frequency coaxial connectors type 9,521ScopeThis part of IEC 61169, which is a sectional specification (SS), provides information and rules for the preparation of detail specifications (DS)

20、for RF coaxial connectors of type 9,52.It describes the interface dimensions for general purpose grade 2 connectors, dimensional details for standard test connectors, grade 0, together with gauging information and the mandatory tests selected from IEC 61169-1, applicable to all DS relating to type 9

21、,52 connectors.This specification indicates the recommended performance characteristics to be considered when writing a DS and covers test schedules and inspection requirements.2Normative referencesThe following referenced documents are indispensable for the application of this document. For dated r

22、eferences, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies.IEC 61169-1:1992, Radio-frequency connectors Part 1: Generic specification General requirements and measuring methods3Interface dimensions3.1Interface3.

23、1.1GeneralAll dimensions are in millimetres.All undimensioned pictorial configurations are for reference purposes only.3.1.2DimensionsFigures 1, 2 and 3 provide dimensions for sliding connectors, screw coupling connectors and standard test connectors respectively.9,1 min.2,35 +0,030,08+0,431 +0,30,1

24、7,11 00,8 0,42 max.8,5 min.9,525 0,05Cone or radiusIEC 105/07Figure 1a Sliding male connector7,54 min.+1,50,5 0IEC 106/07Figure 1b Sliding female connectorFigure 1 Sliding connector+0,437,11 04 0,54 min.Optional sealing gasketM14 1IEC 107/07Figure 2a Screw coupling male connectorM14 15 min.IEC 108/0

25、7Figure 2b Screw coupling female connectorFigure 2 Screw coupling connector9,1 min.2,35 0,01+0,437,11 01 +0,30,10,8 0,48,5 0,022 max.4 min.9,525 0,05M14 1IEC 109/07M14 1Figure 3a Standard test male connector7,54 min.7,2 min.5 min.+0,23,2 0,020,5 04 slotswidth 0,3 mmlenght 4,5 mmIEC 110/07Figure 3b S

26、tandard test female connectorFigure 3 Standard test connectors3.2Mechanical gauges3.2.1GeneralAll dimensions are in millimetres.All undimensioned pictorial configurations are for reference purposes only.3.2.2Socket connectors Gauges for the resilient outer contactFigure 4 illustrates gauge pins for

27、outer contacts of socket connectors.ab7 0,5IEC 111/07Surface finish: Ra =0,5W eight: 5 NReferenceGauge AGauge BmmmmMin.Max.Min.Max. a b9,5755,09,5855,29,4657,09,4757,2Test sequencea) Steel test pin (A) (Figure 4) shall be inserted at least three times into the outer contact. b) A second steel test p

28、in (B) (Figure 4) shall be inserted into the outer contact.This gauge, when in a vertical downward attitude, shall be retained by the contact.Figure 4 Gauge pins for outer contact of socket connector3.2.3Socket connectors Gauges for the resilient centre contactFigure 5 illustrates gauge pins for cen

29、tre contacts of socket connectors.5 +0,20aR0,500,1Surface finish: Ra =0,5IEC 112/07ReferenceGauge CmmGauge DmmMin.Max.Min.Max. a2,382,392,292,30Test sequencea) Steel test pin (C) (Figure 5) shall be inserted at least three times into the centre contact. b) A second steel test pin (D) (Figure 5) shal

30、l be inserted into the centre contact.This gauge, when in a vertical downward attitude, shall be retained by the contact. This gauge will have a mass (weight) of 0,25 N.Figure 5 Gauge pins for centre contact of socket connector4Quality assessment procedures4.1GeneralThe following subclauses provide

31、recommended ratings, performance and test conditions to be considered when writing a detail specification (DS). They also provide an appropriate schedule of tests with minimum levels of conformance inspection.4.2Ratings and characteristicsThe RF connectors defined in this standard are designed for u

32、se with a variety of flexible and semi-rigid coaxial cables and in microwave integrated circuits and similar uncabled applications. Table 1 lists the ratings and characteristics involved.Table 1 Ratings and characteristicsRatings and characteristicsIEC 61169-1 subclauseValueRemarksincluding an y dev

33、iations from standard test methodsElectricalNominal impedanceFrequency rangeReflection factor straight styles a right angle styles solder bucket and PCB mounting styleCentre contact resistance initial after conditioningOuter conductor continuity initial after conditioningInsulation resistance initia

34、l after conditioningProof voltage at sea level b cScreening effectivenessDischarge test (Corona)9.2.19.2.39.2.59.2.69.2.89.2.90-3 GHZ7% up to 2 GHZ10% up to 3 GHZ 5 m 10 m 2,0 m 1 G 1 M750 Vas 90 dBnaShall meet the requirements of9.2.1.1 of IEC 61169-1 when terminating a Zc = 75 cableSee DSSee DSUnder consideration86 kPa - 106 kPaZtMechanicalGauge retention force (resilient contacts) Contact