AKTA-实验室层析柱装柱技术介绍.ppt

上传人:小飞机 文档编号:5415028 上传时间:2023-07-05 格式:PPT 页数:21 大小:219.50KB
返回 下载 相关 举报
AKTA-实验室层析柱装柱技术介绍.ppt_第1页
第1页 / 共21页
AKTA-实验室层析柱装柱技术介绍.ppt_第2页
第2页 / 共21页
AKTA-实验室层析柱装柱技术介绍.ppt_第3页
第3页 / 共21页
AKTA-实验室层析柱装柱技术介绍.ppt_第4页
第4页 / 共21页
AKTA-实验室层析柱装柱技术介绍.ppt_第5页
第5页 / 共21页
点击查看更多>>
资源描述

《AKTA-实验室层析柱装柱技术介绍.ppt》由会员分享,可在线阅读,更多相关《AKTA-实验室层析柱装柱技术介绍.ppt(21页珍藏版)》请在三一办公上搜索。

1、实验室层析柱装柱技术介绍,Column packing,好的柱效是层析成功的关键不同种类的凝胶、不同的层析柱有不同的装柱方法柱效测定的方法层析柱的维护,Column packing,Rabies vaccineSepharose 4 Fast Flow5%column vol sample,Column packing,每米塔板数:N=1600,每米塔板数:N=3500,Column packing,N/m=5.54(Ve/Vh)2100/L,As=b/a,Column packing,检测装柱效果一般用0.5%(30um介质)或1%(90um介质)柱体积的1%丙酮测柱效和峰形The line

2、ar flow rate should be 30 cm/h for 34 m and 50 m media and 20 cm/h for 90 m media,线性流速对体积不同的柱子来说,体积流速不能直接用作比较,一般都换算成线性流速,再作比较:体积流速(ml/min)x 60 线性流速(cm/hr)=揪揪揪揪揪揪 柱子横切面积(cm2),Column packing,Column packing,It is important that the column is properly equilibrated before thepacking is evaluated(2 column

3、 volumes).It is preferable to runthree test runs to see whether the test values are stable.If a poor result improves during this test,the reason can be that thecolumn was not properly equilibrated.To check that the bed is stable,run the column at 70%packingpressure for 20 hours and test it again(pre

4、ferably three test runs).Note that pressure spikes may cause poor packing(cracking).Ifthis happens,an air trap and a pressure relief valve are neededbetween the pump and the column.The pressure relief valveshould be placed between the air trap and column.,Column packing,装柱注意点,选择一根设计良好的柱子仔细混合均匀凝胶浆在生产

5、时使用柱子的温度下装柱用平缓的动作将凝胶浆一次性加入柱子中用恒压或恒流装柱稳定和平衡凝胶柱床检查柱效,必要时重装,Column packing,用空柱子须留意.,使用调节器(flow adaptor)-保护柱床的同时更可提高分辨率,节省凝胶柱子物料须生物兼容,并有优良的化学抗性加上装柱器(packing reservoir),可一次把凝胶装满柱子,大大提高柱效,尤其是凝胶过滤柱。柱子的过滤网孔径应该是凝胶颗粒的1/3,一般10mm孔 径就够用,如用SOURCE15介质装C柱和XK柱,须换上5mm的网,Column packing,Sepharose FF based gel:Sepharose

6、 Q,DEAE,SP,Phenyl 1.the 75%slurry just before packing.2.Ideally,Fast Flow media are packed at a con stant pressure not exceeding 3 bar(0.3 MPa)for XK columns.3.If the packing equipment does not include a pressure gauge,use a packing flow rate of at least 400 cm/h(15 cm bed height,25).If recommended

7、pressure or flow rate can not be obrained,use the maximum flow the pump can deliver,this should also give a easonably well-packed gel.Do not exceed 75%of the packing flow rate in subsequent chromatographic procedures.,Column packing,Sepharose 4 Fast Flow50-75%slurry just before packing.110 cm/h flow

8、 rate and the pressure should not be increased beyond 1.0 bar3-5mm blow the settled bed was made,Column packing,Sepharcyl S HR Flow rates given below.Pack the gel in STEP 1 for 2 hours or until the gel has reached a constant height,then increase the flow rate to the value listed for STEP 2 and pack

9、for 60 minutes.,Packing flow rates(ml/h):Column STEP 1 STEP 2 XK 16/70 60 110 XK 16/100 60 100 XK 26/70 150 300 XK 26/100 150 270 XK 50/100 500 800,Column packing,Superdex 75,200 pg50%slurry1 step:20cm/h flow rate,2 hour2 step:step the pressure is held at 3 bar,1hour,Column packing,Sephadex G-2550%s

10、lurry400 cm/h flow rate3mm blow the settled bed was made,层析柱的使用及维护,柱的平衡:在装柱及做完一个层析后,用至少5倍柱体积的缓冲液平衡或柱的流出液的电导和pH稳定。柱的再生:用高离子强度的缓冲液(1M NaCl)洗脱或改变pH。,在位清洗(CIP),离子性吸附的蛋白:Wash with 0.5 CV 2M NaCl.Contact time 15 min.沉淀的、疏水性结合的蛋白及脂蛋白:1 M NaCl at 40 cm/h,1-2 hours.脂类及非常强结合的疏水性蛋白:2-4 CV 0.5%非离子去垢剂(或1%醋酸)1-2 小时。使用梯度方式70%的乙醇或30%的异丙醇,2-4 CV 1-2 小时。,柱子的保存,0.15 mol/L NaAc pH 4.020%ethanol0.01 mol/L NaOH0.05%sodium azide,怎样获得好的层析结果,检测柱效清洗或重装柱子减少样品上样体积,不要超量控制流速严格控制缓冲液、样品的pH及电导改用其它种类的凝胶,谢谢欢迎您随时和我们联系北京(010)8838 5742上海(021)5080 0260广州(020)8732 0255香港(852)2811 7575,

展开阅读全文
相关资源
猜你喜欢
相关搜索

当前位置:首页 > 生活休闲 > 在线阅读


备案号:宁ICP备20000045号-2

经营许可证:宁B2-20210002

宁公网安备 64010402000987号