《IntelliNova智能监控系统.ppt》由会员分享,可在线阅读,更多相关《IntelliNova智能监控系统.ppt(14页珍藏版)》请在三一办公上搜索。
1、System architecture,OPCServerOPCClient,LINX Link between the Database and The Commander Units,DataBase,Commander Unit(CU),Basic Building Blocks,Bearing Monitoring Unit,Vibration Monitoring Unit,Analog Output Unit,Analog Monitoring Unit,Commander Unit System Architecture,Commander UnitConnections and
2、 Indications,On/Off LEDPower supply 18-36 V DC On/Off switch(breaks power)”Unit is operative”LED”Unit has a LINX connection”LED4 general digital outputs4 RPM or digital inputsRS232 connection used for test/calibrationEthernet connectionSD memory with read/write LED,Technical Highlights,GeneralUp to
3、32 channels/Unit:vibration,SPM,analogue in 4-20mA/0-10V and analogue out(groups of 8)Bearing Monitoring Units and Analogue Monitoring Units are processed in parallel(not syncronized)while Vibration Measurements and SPM Spectrum measurements requires the common DSP resourceMonitoring Modules can be m
4、ixed freely on a commander unitAll measuring units are calibrated separately and can be handled separately,Bearing Monitoring Unit,8 multiplexed channelsdBm/dBc,LR/HR and SPM SpectrumdBm/dBc:one measurement every 1.5 seconds,LR/HR:one measurement every 20 secondsConfigurable between 42000 and 40000
5、transducers,Vibration Monitoring Unit,2 channel simultaneous vibration measurement(on even/odd channels)Signal filters implemented in software(DSP)-Highpass,lowpass,bandpass,enveloping filters-Integration up to 2 steps(acc-vel-disp)-Hardware reduced to a minimum no temperature drift,no aging,minimal
6、 calibration,-flexible(easy to add new filter frequencies)Lower frequency limits:0.5,2,10,100 max:40 KHz24 bit Delta-Sigma A/D converterPossible to measure DC(bias voltage),Analog Monitoring Unit,Measures 8 channels 0-20 mA and 2 channels 0-10V(10 bit A/D Converter)Scans all 8 channels in 8 secondsM
7、emory for previous reading per channel,Analog Output 4-20mA,8 channels 4-20 mAA measuring assignment can be configured to control each output,DB,LINX,Measurement Tasks,DB,LINX,IntellilogicData Flow and Alarms,DB,LINX,Intellicheck,Configuration,sequence files and buffered datavia SD card,Initial conf
8、iguration like:-IP address-Choice of dynamic or static IP address-Commander unit name-Server name for LINX-Etc Can be done either via a directly connected PC(crossed LAN cable)or via the SD card.FSS is used in both cases.A sequence file can be loaded to the Commander Unit from LINX via the SD card.Buffered measurements can be downloaded to LINX via the SD card.,