《电导法测定弱电解质电离常数及难溶盐溶解度.ppt》由会员分享,可在线阅读,更多相关《电导法测定弱电解质电离常数及难溶盐溶解度.ppt(30页珍藏版)》请在三一办公上搜索。
1、电导法测定弱电解质电离常数及难溶盐溶解度,Determination of Weak ElectrolyteIonizationConstant and solubility of Hardly Dissolved Salt by Conductivity Methods,Content,Purposes and Demands PrincipleApparatus and Reagent procedureData Records and Processing QuestionsAttentions Demonstrated,Purposes and Demands,1.To determi
2、ne the ionization constant of acetic acid.2.To determine the solubility of calcium sulphate.3.Master the operation of conductivity detector.,Principle,1)Determination of weak electrolyte ionization constant.At certain temperature,the equilibrium of acetic acid ionization in water can be written as f
3、ollow HAc=H+AcInitial c 0 0eg c(1-)c c,So,ionization constant could be expressed as:,Ionization degree in formula is related with molar conductivity.That is:molar conductivity when concentration is c 0ultimate molar conductivity if solution is diluted illimitably 0=L+L(the sum of positive and negati
4、ve ion molar conductivity)can be lookup on literatures.,K conductivity(s/cm or ms/cm ors/cm).It can be determined through experiment.C concentration(molL-1 or N L1),Adding equation.into.,we obtain that Draw a graph of cm against 1/and get a beeline of which slope is:slope=0 2 KcLook for 0 on literat
5、ures,and account out Kc.,实验原理,2)Determination of hardly dissolved salts solubility Kc=Ksolution KH2OKsolution conductivity of solutionKH2O conductivity of water,Apparatus and Reagent,Conductivity detector 1Super thermostatic trough 1Conical flask(250ml)2Conical flask(50ml)3Pipette(20ml)2Beaker(100ml
6、)10.1000M HAc solutionCaSO4(A.R),Procedure,1)Determination of weak electrolyte ionization constant 1.Regulate the temperature of thermostatic trough at 250.1.Put two conical flasks one of which is filled with 120-130ml conductive water and another with 40ml HAc(0.1M)into thermostatic trough,and main
7、tain the temperature at this level for 20 min.,2.Clean a platinum black electrode with distilled water and blotted it up by the use of filter paper(dont touch platinum-black).Put the electrode into the conical flask filled with 40ml HAc and detect the conductivity.,Remove l of HAc solution and compl
8、ement with 20ml conductive water that has been kept temperature constant,shaking up.After temperature is kept constant for 5 min,determine the conductivity of the solution above.,Repeat the same dilution procedure to confect other five HAc solution of different concentration showed in the table belo
9、w.Determine six conductivities of these solutions and complete the table.,2)Determination of hardy dissolved salts solubility1.Weigh 1g CaSO4 solid,put it into 100ml beaker and dissolve with distilled water.Heat the solid-liquid mixture up to boiling point.,Drop off superstratum liquid.Repeat the sa
10、me procedure twice and think about the meaning of this operation.,2.Dissolve the solid adequately with 80ml distilled water and heat it up to boiling point.Cool the liquid down to room temperature,collect clear topper liquid and take it to thermostatic trough.,Fill the beaker with 40ml distilled wat
11、er.Repeat the above procedure twice.When the temperature keeps constant,measure the conductivity of these three saturated CaSO4 solutions.,3.Get 40ml of conductive water which has been kept temperature constant and measure its conductivity.Figure out the conductivity of CaSO4 by the formula we have
12、learned.,(1)Determination of weak electrolyte ionization constant by conductivity methods,Data Records and Processing,Draw a graph of cm against 1/and calculate its slope.And as we know:+0(literatures)349.840.9390.7(-1cm-1mol-1)Then,Kc would be figure out,that is Kc=,实验数据记录和处理,2)Determination of sol
13、ubility of hardly dissolved salt 1.Conductivity of water,实验数据记录和处理,2.conductivity of CaSO4 saturated solution,Kcaso4=Ksolution-Kwater,Questions,1.Why should we use the thermostatic trough in the experiment?2.Why cant we determine conductivity of solution with direct current?3.Why do we have to wash
14、CaSO4 solid and use superstratum liquid for determination in the preparation process of CaSO4 saturated solution?,Attentions,1.Conductance electrode must be below liquid-level.2.Determination must be operated in constant temperature.3.Conductivity detector must be proofread before each determination
15、.,Outline in the use of DDS-11A conductivity detector,1.Switch on the electrical source and allow it warm-up for several min(until pointer turns stable).2.Turn the constant knob to be electrode constant(its been checked and determined by the factory).,3.Emendation.Determine conductivity of H2O on lo
16、w round and HAc is on high round.Turn the knob,driving the pointer point to full scale namely 1.0.,4.Determination.Choose proper measuring range from large range to small one and try to control the pointer pointing to the full scale in order to get accurate data.That just is:1041031021010.1,5.Reading and record.The data marker is in the form of 10 x10-6(s/cm).X stands for 4,3 or 2 and 1 in the measuring range.,