【AS澳大利亚标准】AS 1289.3.3.1 Methods of testing soils for engineering purposes Method 3.3.1 S.doc

上传人:sccc 文档编号:5185274 上传时间:2023-06-11 格式:DOC 页数:5 大小:89KB
返回 下载 相关 举报
【AS澳大利亚标准】AS 1289.3.3.1 Methods of testing soils for engineering purposes Method 3.3.1 S.doc_第1页
第1页 / 共5页
【AS澳大利亚标准】AS 1289.3.3.1 Methods of testing soils for engineering purposes Method 3.3.1 S.doc_第2页
第2页 / 共5页
【AS澳大利亚标准】AS 1289.3.3.1 Methods of testing soils for engineering purposes Method 3.3.1 S.doc_第3页
第3页 / 共5页
【AS澳大利亚标准】AS 1289.3.3.1 Methods of testing soils for engineering purposes Method 3.3.1 S.doc_第4页
第4页 / 共5页
【AS澳大利亚标准】AS 1289.3.3.1 Methods of testing soils for engineering purposes Method 3.3.1 S.doc_第5页
第5页 / 共5页
亲,该文档总共5页,全部预览完了,如果喜欢就下载吧!
资源描述

《【AS澳大利亚标准】AS 1289.3.3.1 Methods of testing soils for engineering purposes Method 3.3.1 S.doc》由会员分享,可在线阅读,更多相关《【AS澳大利亚标准】AS 1289.3.3.1 Methods of testing soils for engineering purposes Method 3.3.1 S.doc(5页珍藏版)》请在三一办公上搜索。

1、1 AS 1289.3.3.12009Australian StandardMethods of testing soils for engineering purposesMethod 3.3.1: Soil classification tests Calculation of the plasticity index of a soil1 SCOPEThis Standard sets out a method to calculate the plasticity index of a soil as derived from the liquid limit and the plas

2、tic limit of a soil.2 REFERENCED DOCUMENTSThe following documents are referred to in this Standard: AS1289Methods of testing soils for engineering purposes1289.3.1.1 Method 3.1.1: Soil classification testsDetermination of the liquid limit of a soilFour point Casagrande method1289.3.1.2 Method 3.1.2:

3、 Soil classification testsDetermination of the liquid limit of asoilOne point Casagrande method (subsidiary method)1289.3.2.1 Method 3.2.1: Soil classification testsDetermination of the plastic limit of a soilStandard method3 PROCEDUREThe procedure shall be as follows:(a) Determine liquid limit in a

4、ccordance with AS 1289.3.1.1 or AS 1289.3.1.2. If the liquid limit cannot be determined the soil is considered to be non-plastic and the plastic limit need not be determined.(b)If a liquid limit value has been determined, perform the plastic limit in accordance with AS 1289.3.2.1 ensuring that the s

5、ame method of preparation of the soil for the liquid limit and plastic limit has been followed.ON4 CALCULATI Using the reported values of wL and wP, calculate the plasticity index (IP) from thefollowing equation: Standards AustraliawhereIP= wLwPAS 1289.3.3.12009IP = plasticity index, in percent.wL =

6、 liquid limit, in percent.wP = plastic limit, in percent.AS 1289.3.3.12009 25 TEST REPORTThe following shall be reported:(a)The plasticity index (IP), in percent, when both the liquid limit and the plastic limit are determined.(b)When the liquid limit or the plastic limit cannot be determined, repor

7、t the plasticity index as NP (i.e., non-plastic), together with the liquid or plastic limit, if either has been determined.(c) When the plastic limit is equal to or greater than the liquid limit, report the plasticity index as 0 (zero) and also report both the liquid limit and the plastic limit.(d)T

8、he method used to determine the liquid limit, i.e., AS 1289.3.1.1 or AS 1289.3.1.2. (e)Method of preparation and the history of the sample.(f) Reference to this method, i.e., AS 1289.3.3.1. Standards Australiawww.standards.org.au3 AS 1289.3.3.12009NOTESAS 1289.3.3.12009 4This Australian Standard was

9、 prepared by Committee CE-009, Testing of Soils for Engineering Purposes. It was approved on behalf of theCouncil of Standards Australia on 9 December 2008 and published on 6 February 2009.The following are represented on Committee CE-009: AUSTROADSAssociation of Geotechnical Testing Authorities (Ql

10、d)Australian Building Codes BoardAustralian Chamber of Commerce and IndustryAustralian Geomechanics SocietyAustralian Stabilisation Industry AssociationCement Concrete and Aggregates AustraliaDepartment of Planning and Infrastructure (NT)Engineering and Construction Laboratories AssociationEngineers

11、 AustraliaNational Association of Testing Authorities AustraliaUniversity of MelbourneUniversity of SydneyVictorian Construction Materials Laboratories AssociationKeeping Standards up-to-dateStandards are living documents which reflect progress in science, technology and systems. To maintain their c

12、urrency, all Standards are periodically reviewed, and new editions are published. Between editions, amendments may be issued. Standards may also be withdrawn. It is important that readers assure themselves they are using a current Standard, which should include any amendments which may have been pub

13、lished since the Standard was purchased.Detailed information about Standards can be found by visiting the Standards Web Shop at .au and looking up the relevant Standard in the on-line catalogue.We also welcome suggestions for the improvement in our Standards, and especially encourage readers to noti

14、fy us immediately of any apparent inaccuracies or ambiguities. Contact us via email at mailstandards.org.au, or write to the Chief Executive, Standards Australia Limited, GPO Box 476, Sydney, NSW 2001.Originated as AS A89.4A1966.Revised and redesignated as AS 1289.C3.11977. Revised and redesignated

15、as AS 1289.3.3.11995. Second edition 2009.This Standard was issued in draft form for comment as DR 06693.COPYRIGHT Standards AustraliaAll rights are reserved. No part of this work may be reproduced or copied in any form or by any means, electronic or mechanical, including photocopying, without the written permission of the publisher.Published by Standards Australia LimitedGPO Box 476, Sydney, NSW 2001, AustraliaISBN 0 7337 9006 2 Printed in AustraliaThis page has been left intentionally blank.