微流体芯片ppt课件.ppt

上传人:sccc 文档编号:5378169 上传时间:2023-07-01 格式:PPT 页数:30 大小:5.67MB
返回 下载 相关 举报
微流体芯片ppt课件.ppt_第1页
第1页 / 共30页
微流体芯片ppt课件.ppt_第2页
第2页 / 共30页
微流体芯片ppt课件.ppt_第3页
第3页 / 共30页
微流体芯片ppt课件.ppt_第4页
第4页 / 共30页
微流体芯片ppt课件.ppt_第5页
第5页 / 共30页
点击查看更多>>
资源描述

《微流体芯片ppt课件.ppt》由会员分享,可在线阅读,更多相关《微流体芯片ppt课件.ppt(30页珍藏版)》请在三一办公上搜索。

1、,Multiple and High-Throughput Droplet Reactions via Combination of Microsampling Technique and Microfluidic Chip,Members:李娜 冯双霞 徐秋燕 刘婷婷 聂怀军,Contents,Background,Experiment,ABSTRACT,Discussion,ABSTRACT,Microdroplets oer unique compartments for accommodating a large number of chemical and biological re

2、actions in tiny volume with precise control.A major concern in droplet-based microuidics is the diculty to address droplets individually and achieve high throughput at the same time.,Here,we have combined an improved cartridge sampling technique with a microuidic chip to perform droplet screenings a

3、nd aggressive reaction with reagent consumption.Our combined device provides a simple model to utilize multiple droplets for various reactions with low reagent consumption and high throughput.,Background,A large number of reactions can be independently miniaturized into tiny droplets ranging from na

4、noliter to picoliter sizes without having to increase the chip size and complexity.,Microfluidic chips have provided a powerful platform for accomplishing droplet formation and manipulation within one chip of only a few square centimeters in size.,Advantages,Over the past few years,droplet-based mic

5、rouidics has attracted increasing attention.,Background,Droplet generation for multiple samples is limited by the“world-to-chip”interface problem and cannot be addressed individually,Droplet generation and manipulation functions within one chip can easily interfere with each other and are difficult

6、To balance,despite being separated by a long,winding channel.,Drawback,Passive droplet formation methods:,Innovate,This context shows a hybrid device:the cartridge droplet generation technique combined with a microfluidic chip.They improved the cartridge technique with a novel movement scheme:the ca

7、pillary,instead of the multiwell plate,was moved by a digital and automatic manipulator to aspirate different samples or the covering oil.,The hybrid droplet device for generation and manipulation consists of four major components.(a)manipulator(b)multiwell plate(c)capillary(d)PDMS chip,Three genera

8、l steps,load the multiwell plate with different samples,cover with a layer of oil,and input theparameters of the desired droplet array into the controller via a PC,start the controller to aspirate certain volumes of samples and oil into the Capillary sequentially,introduce the generated droplets int

9、o the PDMS chip for merging,mixing,detection,or other manipulation.,Laboratory reagent,silicone oil,FeCl24H2O(SigmaAldrich),FeCl36H2O(Acros Organics),ammonium hydroxide solution(28%NH3 Fluka),and hydrochloric acid(37%HCl,Acros Organics),Improved Sampling Technique,Combined Droplet Device Performance

10、,High-Throughput Droplet Screening,Aggressive Droplet Reaction,Improved Sampling Technique,The capillary aspirates the oil when the cantilever remains in the“up”state.When the cantilever is triggered to stay in the“down”state,the capillary aspirates the sample.The residence time in the oil(TO)and sa

11、mple(TS)could be adjusted respectively to generate droplets with desired distance and volume.,(c)Relative intensity was measured along the channel starting from top right corner.The intensity of fluorescein and DI water droplet does not decrease or increase,which indicates that no cross-contaminatio

12、n between these two samples was detected.,(b)Droplet array was generated by sequentially aspirating 50 uM fluorescein and DI water.,Combined Droplet Device Performance,Here,the merging of droplets was demonstrated in a PDMS chip.The droplets fusion does not depend on droplet distance but droplet vel

13、ocity and Vd/Vc.After mixing completely,the merged droplet was output to a sinuous channel for display and detection.,In the rst application,a series of Ai and Bm,n(i=1 2,m=1 3,and n=1 6)were generated.A1and A 2 are Fluo-4 and Rhod-2 solutions with the same concentration(10.8 M),which are indicators

14、 that exhibit an increase in uorescence(green/red)upon metal ion bonding.A value of m=1 3 represent metalsion solutions of LaIII,Yb III,and YIII,respectively,while n=1 6 are six dierent metal ion concentrations(0,2.5,5,10,20,and40 M)of these solutions.The droplet array contains 72 1-nLdroplets,High-

15、Throughput Droplet Screening,The 36 pairs of droplet reactions used 72 nL of solutionand required 1.8 min to complete.Therefore,the reagentconsumption for each measurement could be reduced to 1 nL per sample,and the reaction throughput is 1200 h1,which can be much faster by increasing the ow velocit

16、y.The screening droplets could be stored in the PDMS chip after we stopped the vacuum.,Aggressive Droplet Reaction,From these images,we found that the coprecipitation is so fast that it immediately forms particles when two droplets come into contact with each other.Moreover,in each volume ratio,the

17、precipitation initiated bythe fusion of two droplets did not block the microchannel at such high concentrations.Such exible,controllable and miniaturized reaction conditions are extremely suitable for aggressive,fast,or even explosive reactions that generate precipitation or heat.,Discussion,The car

18、tridge droplet generation method provides an efficient way for introducing different nanoliter droplets into the microfluidic chip.the microfluidic chip offers a platform for delicate manipulation such as merging.,This feature is valuable for reducing the reaction screening and optimization cost and

19、 time and is particularly useful for drug screening.,Compared with the other cartridge droplet generation,our design used a digital and automatic manipulator to move the capillary instead of the multiwell plate.,Discussion,Subsequently,the covering oil was ingeniously used as a carrier uid(continuou

20、s-phase)to avoid evaporation and cross-contamination.,The droplet generation throughputs in our sampling device increased to 1 5 s per droplet,which is ecient and versatile for arbitrary,multiple,and high-throughput droplet generation and could be increased by increasing the ow velocity.,This improved cartridge technique and microuidic chip were integrated to make use of their respective advantages for performing response calibrations and aggressive reaction and screening multiple reaction conditions with minimal(nL)reagent consumption.,Thank You!,2012.11.19,

展开阅读全文
相关资源
猜你喜欢
相关搜索

当前位置:首页 > 建筑/施工/环境 > 农业报告


备案号:宁ICP备20000045号-2

经营许可证:宁B2-20210002

宁公网安备 64010402000987号