【UL标准】UL 96A Installation Requirements for Lightning Protection Systems.doc

上传人:sccc 文档编号:5216340 上传时间:2023-06-14 格式:DOC 页数:62 大小:6.78MB
返回 下载 相关 举报
【UL标准】UL 96A Installation Requirements for Lightning Protection Systems.doc_第1页
第1页 / 共62页
【UL标准】UL 96A Installation Requirements for Lightning Protection Systems.doc_第2页
第2页 / 共62页
【UL标准】UL 96A Installation Requirements for Lightning Protection Systems.doc_第3页
第3页 / 共62页
【UL标准】UL 96A Installation Requirements for Lightning Protection Systems.doc_第4页
第4页 / 共62页
【UL标准】UL 96A Installation Requirements for Lightning Protection Systems.doc_第5页
第5页 / 共62页
点击查看更多>>
资源描述

《【UL标准】UL 96A Installation Requirements for Lightning Protection Systems.doc》由会员分享,可在线阅读,更多相关《【UL标准】UL 96A Installation Requirements for Lightning Protection Systems.doc(62页珍藏版)》请在三一办公上搜索。

1、UL 96AInstallation Requirements forLightning Protection SystemsUL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM ULThis PDF Standard downloaded from UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSIO

2、N FROM ULMAY 23, 2007 UL 96Atr1Underwriters Laboratories Inc. (UL)333 Pfingsten RoadNorthbrook, IL 60062-2096UL Standard for Safety for Installation Requirements for Lightning Protection Systems, UL 96A Twelfth Edition, Dated May 23, 2007Summary of TopicsThis new edition of UL 96A includes the follo

3、wing: Changes to align with NFPA 780Change to allow use of newer materials that are compatible with membrane roofing systemsAdditional exception to replace a previous reference to a Practical Application Guideline(PAG)New illustration showing zones of protection and applicable computations determine

4、d by using the rolling sphere conceptRewording of the scope to clarify the requirements covering the application and inspection for the installation of lightning protection on all types of new and existing structuresClarification of the requirements for Protection for Miscellaneous StructuresThe ter

5、ms “inductance and conductance”, when referring to metal bodies, was removed, and clarified with terms such as “strike termination devices” and “grounded metal bodies”. Also, the requirement for the use of the mega-ohm tester and continuity tester to determine whether a body is isolated was deletedR

6、equirement modifications to ground terminals located inside a structure, multiple ground rods, and ground ring electrodesRevision to Common Ground requirement Revision to zone of protection requirement Addition of sprinkler lines and galvanized steel Change in requirement to down conductor Miscellan

7、eous editorial revisionsThe new requirements are substantially in accordance with ULs Proposal(s) on this subject dated March27, 2006 and March 23, 2007.The UL Foreword is no longer located within the UL Standard. For information concerning the use and application of the requirements contained in th

8、is Standard, the current version of the UL Foreword is located on ULStandardsInfoNet at: UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM ULtr2MAY 23, 2007 UL 96AThis PDF Standard downloaded from The master for this Standard at ULs Northbrook Of

9、fice is the official document insofar as it relates to a UL service and the compliance of a product with respect to the requirements for that product and service, or if there are questions regarding the accuracy of this Standard.ULs Standards for Safety are copyrighted by UL. Neither a printed copy

10、of a Standard, nor the distribution diskette for a Standard-on-Diskette and the file for the Standard on the distribution diskette should be altered in any way. All of ULs Standards and all copyrights, ownerships, and rights regarding those Standards shall remain the sole and exclusive property of U

11、L.All rights reserved. No part of this publication may be reproduced, stored in a retrieval system, or transmitted in any form by any means, electronic, mechanical photocopying, recording, or otherwise without prior permission of UL.Revisions of UL Standards for Safety are issued from time to time.

12、A UL Standard for Safety is current only if it incorporates the most recently adopted revisions.UL provides this Standard as is without warranty of any kind, either expressed or implied, including but not limited to, the implied warranties of merchantability or fitness for any purpose.In no event wi

13、ll UL be liable for any special, incidental, consequential, indirect or similar damages, including loss of profits, lost savings, loss of data, or any other damages arising out of the use of or the inability to use this Standard, even if UL or an authorized UL representative has been advised of the

14、possibility of such damage. In no event shall ULs liability for any damage ever exceed the price paid for this Standard, regardless of the form of the claim.UL will attempt to answer support requests concerning electronic versions of its Standards. However, this support service is offered on a reaso

15、nable efforts basis only, and UL may not be able to resolve every support request. UL supports the electronic versions of its Standards only if they are used under the conditions and operating systems for which it is intended. ULs support policies may change from time-to-time without notification.UL

16、 reserves the right to change the format, presentation, file types and formats, delivery methods and formats, and the like of both its printed and electronic Standards without prior notice.Purchasers of the electronic versions of ULs Standards for Safety agree to defend, indemnify, and hold UL harml

17、ess from and against any loss, expense, liability, damage, claim, or judgement (including reasonable attorneys fees) resulting from any error or deviation introduced while purchaser is storing an electronic Standard on the purchasers computer system.If a single-user version electronic Standard was p

18、urchased, one copy of this Standard may be stored on the hard disk of a single personal computer, or on a single LAN file-server or the permanent storage device of a multiple-user computer in such a manner that this Standard may only be accessed by one user at a time and for which there is no possib

19、ility of multiple concurrent access.If a multiple-user version electronic Standard was purchased, one copy of the Standard may be stored on a single LAN file-server, or on the permanent storage device of a multiple-user computer, or on an Intranet server. The number of concurrent users shall not exc

20、eed the number of users authorized.Electronic Standards are intended for on-line use, such as for viewing the requirements of a Standard, conducting a word search, and the like. Only one copy of the Standard may be printed from each single-user version of an electronic Standard. Only one copy of the

21、 Standard may be printed for eachUL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM ULMAY 23, 2007 UL 96Atr3authorized user of a multiple-user version of an electronic Standard. Because of differences in the computer/software/printer setup used by

22、 UL and those of electronic Standards purchasers, the printed copy obtained by a purchaser may not look exactly like the on-line screen view or the printed Standard.An employee of an organization purchasing a UL Standard can make a copy of the page or pages being viewed for their own fair and/or pra

23、ctical internal use.The requirements in this Standard are now in effect, except for those paragraphs, sections, tables, figures, and/or other elements of the Standard having future effective dates as indicated in the note following the affected item. The prior text for requirements that have been re

24、vised and that have a future effective date are located after the Standard, and are preceded by a SUPERSEDED REQUIREMENTS notice.New product submittals made prior to a specified future effective date will be judged under all of the requirements in this Standard including those requirements with a sp

25、ecified future effective date, unless the applicant specifically requests that the product be judged under the current requirements. However, if the applicant elects this option, it should be noted that compliance with all the requirements in this Standard will be required as a condition of continue

26、d Listing and Follow-Up Services after the effective date, and understanding of this should be signified in writing.Copyright 2007 Underwriters Laboratories Inc.This Standard consists of pages dated as shown in the following checklist:PageDate1-54 . May 23, 2007SA1-SA2 . May 23, 2007UL COPYRIGHTED M

27、ATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM ULtr4MAY 23, 2007 UL 96AThis PDF Standard downloaded from No Text on This PageUL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM ULMAY 23, 20071UL 96AStandard

28、for Installation Requirements for Lightning Protection SystemsPrior to the sixth edition, previous numbered and unnumbered editions covering Installation Requirements for Lightning Protection Systems have been published since 1916. The sixth edition was titled Installation Requirements for Master La

29、beled Lightning Protection Systems.Sixth Edition March, 1958Seventh Edition April, 1960Eighth Edition June, 1963Ninth Edition April, 1982Tenth Edition May, 1994Eleventh Edition July, 2001Twelfth EditionMay 23, 2007An effective date included as a note immediately following certain requirements is one

30、 established by Underwriters Laboratories Inc.Revisions of this Standard will be made by issuing revised or additional pages bearing their date of issue. A UL Standard is current only if it incorporates the most recently adopted revisions, all of which are itemized on the transmittal notice that acc

31、ompanies the latest set of revised requirements. Comments or proposals for revisions on any part of the Standard may be submitted to UL at any time. Proposals should be submitted via a Proposal Request in ULs On-Line Collaborative Standards Development System (CSDS) at .COPYRIGHT 2007 UNDERWRITERS L

32、ABORATORIES INC.UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL2INSTALLATION REQUIREMENTS FOR LIGHTNING PROTECTION SYSTEMS - UL 96AMAY 23, 2007This PDF Standard downloaded from No Text on This PageUL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR F

33、URTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM ULMAY 23, 2007INSTALLATION REQUIREMENTS FOR LIGHTNING PROTECTION SYSTEMS - UL 96A3CONTENTSINTRODUCTION1 Scope . .52 Components . .53 Units of Measurement . .64 Undated References . .65 Glossary . .6PROTECTION FOR ORDINARY BUILDINGS6 General

34、 . .107 Materials . .118 Strike Termination Devices . .128.1 General . .128.2 Zone of protection . .128.3 Dormers . .148.4 Intermediate ridges . .148.5 Irregular roof lines . .148.6 Open areas . .148.7 Domed or curved roofs . .148.8 Chimneys, vents and roof top metal bodies . .159 Conductors . .269.

35、1 General . .269.2 Roof conductors . .309.3 Down conductors . .319.4 Interconnecting conductors . .3310 Grounding . .3310.1 General . .3310.2 Multiple ground rods . .3610.3 Shallow topsoil . .3810.4 Common grounds . .3910.5 Concrete-encased electrodes . .3910.6 Ground ring electrode . .4011 Metal Bo

36、dies Subject to Direct Strikes . .4012 Connectors and Fittings . .4413 Surge Protection . .4514 Concealed Installations . .4515 Structural Steel Framing . .46PROTECTION FOR MISCELLANEOUS STRUCTURES16 General . .48PROTECTION FOR HEAVY-DUTY STACKS17 Mechanical Execution of Work . .4918 Components . .4

37、919 Corrosion Protection . .4920 Air Terminals . .4921 Conductors . .51UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL4INSTALLATION REQUIREMENTS FOR LIGHTNING PROTECTION SYSTEMS - UL 96AMAY 23, 2007This PDF Standard downloaded from 22 Fasteners .